LG Laundry Center / Stacked Washer-Dryer
LG Laundry Center / Stacked Washer-Dryer
Customer complaint: Not heating like it should. Initial visit (Nov 23) — Mike S: Reported concern The dryer was evaluated for a heating concern. Assessment During inspection, the outside vent was found to be completely clogged with lint. Access to the vent pipe was very limited, which allowed little lint to be removed by hand. This duct runs under the house and will require cleaning by a professional vent cleaning service. A major restriction is also present between the dryer and the outside vent. The unit's temperature was monitored on the normal and delicate cycles and reached about 150°F. A restricted vent limits airflow, which can lengthen drying times and affect how the dryer heats and cycles. Accurate testing cannot be completed until the restriction is cleared. The suspected cause is the clog. Next steps The dryer vent should be professionally cleaned first. The customer was advised that if the unit still does not heat properly after the vent cleaning, a second service visit will be needed for further evaluation. This visit is complete for now.