Explore 282 preserved service records across our communities.
Preserved service history
Whirlpool Range
During diagnostics, I found the “Bake” igniter was faulty. I installed new “Bake” igniter and tested unit to 350 degrees. No further issues found. Job completed.
GE Dishwasher
During inspection, when initiated a cycle, I immediately found a large leak coming from underneath the unit. I found the pump seal has failed causing the leak. Installed new parts and tested unit. No further issues found. Job completed.
Electrolux Cooktop
During diagnostics, the unit was turned off at the breaker on arrival. I flipped the breaker to get power. I tested and had power at the junction block. The unit would not respond to touch at all. I could not get the unit to power up. Also, after flipping the breaker on, the touch panel glass starts to get hot where the power button is. Faulty touch panel and PCB.
Frigidaire Range
I installed new parts and tested the unit to 350 degrees. Unit is functioning normally again.
Job completed. During testing, I found one code.
F-16 Potential Meter Arm Failure
The unit will operate on broil, but not bake. Both elements tested good.
Will need to replace both oven potentiometers.
GE Dishwasher
Insatlled new parts. Teated unit and found no further issues. Job completed.
During inspection, I found a leak at the sump assembly. Also there is an intermittent inlet water valve that is sticking.
Lg Refrigerator
During inspection, I pulled the unit out and removed the back cover. I found the drain hose is not clogged and there is water at the bottom of the catch pan.
defrost and cooling sensors checked good. The noise is coming from the compressor. This exact model is also apart of a lawsuit for the linear compressors. I advised customer to call LG and see about a replacement or compressor repair.
Job completed.
GE Dryer
During diagnostics, I found the heating element has shorted out.
I installed a new heating element. Tested the unit and found it to be operating normally. No further issues found.
Job completed.
Whirlpool Cooktop
Installed new manifold gas assembly. Testwd unit and found no further issues.
Job completed. ,During inspection, I found that the gas valve for the middle burner is seized and cannot be turned.
This valve is attached to the manifold. Looks like we have to order the entire manifold assembly, as I cannot see the valve separate like the others are.
Whirlpool Dishwasher
During diagnostics, I found a code on arrival that was flashings FA-E4 Divertor Valve Issue. I removed the door panel and found live pests inside the door (see picture) The pests have gotten inside the PCB and shorted it out. This is a nest.
Whirlpool Washer,Dryer
Installed cover hold down.
Job completed. I installed all new parts. Tesyed unit and found it to be operating normally.
Job completed.
Maytag Washer
During diagnostics, I found the hot water inlet valve is faulty. It was also completely clogged with sediment.
Installed new inlet valve assembly and tested. No further issues found.
Job completed.
Maytag DISHWASHER
During inspection, I found that the unit was full of water on arrival. The top push handle is missing from the unit. To open the unit you have to force it open due to the missing handle. Also, the lower spray arm has contacted the heating element melting the underside of the spray arm. The drain pump will only work when you tap on it. The unit is 19-years old. First American does not want to fix the unit because of the parts and age. This unit will be replaced. Job completed.