Customer complaint: Deep rumble, not the fan, that shakes the home when the convection. 5934. Initial visit (Oct 13) — Mike S: Reported concern The customer reports an abnormal noise coming from the appliance during operation. Assessment Diagnostic inspection confirmed the noise originates from the lower convection fan. The motor bearings have worn out, preventing smooth fan rotation and generating persistent noise whenever the lower convection system is active. Next steps Plan to replace the lower convection fan assembly to resolve the noise and restore proper airflow and performance. Return visit (Oct 21) — Mike S: We have the wrong part. Reordering new convection fan motor. Third visit (Oct 27) — Mike S: Work performed Installed a new convection fan assembly to restore proper forced-air circulation during cooking cycles. Assessment The oven was set and tested at 350°F to verify heating performance and fan operation. The unit operated normally throughout testing with no additional issues observed, and the repair is complete. Parts installed: Motor Convection. Outcome: Repaired.
- Motor Convection (DG96-00110E) — Installed